Omron S8FS-C03512J Power supply 35 W, 100-240 VAC input, 12 VDC, 3 A output
Availability: Out of stock
₹ 0.0 (+18.0% GST extra)
(Min.Order)
Omron S8FS-C03512J Power Supply Din Rail,Covered type,100 to 240 VAC, Power rating 35 W, Output: 12 VDC, 3 A Terminal block facing forward (Screw terminal), Harmonic current emissions,Omron Smps,Industrial use for switch mode Power Supply Omron
Power rating Item Output voltage |
35 W |
|||||
5 V |
12 V |
15 V |
24 V |
|||
Efficiency * |
115 VAC input |
81% typ. |
83% typ. |
84% typ. |
87% typ. |
|
230 VAC input |
81% typ. |
84% typ. |
84% typ. |
87% typ. |
||
Input |
Voltage range * |
Single phase 85 to 264 VAC, 120 to 370 VDC (The L terminal for the DC input is the positive side and safety standards do not apply.) (Derating is required according to the input voltage. Refer to Derating Curves on page 18.) |
||||
Frequency * |
50 /60 Hz (47 to 450 Hz) |
|||||
Current * |
115 VAC input |
0.66 A typ. |
||||
230 VAC input |
0.41 A typ. |
|||||
Power factor |
--- |
|||||
Leakage current |
115 VAC input |
0.15 mA |
0.15 mA |
0.15 mA |
0.15 mA |
|
230 VAC input |
0.30 mA |
0.25 mA |
0.25 mA |
0.25 mA |
||
Inrush current * (for a cold start at 25°) |
115 VAC input |
16 A typ. |
||||
230 VAC input |
32 A typ. |
|||||
Output |
Rated Output Current |
7 A |
3 A |
2.4 A |
1.5 A |
|
Voltage adjustment range * |
-10% to 10% (with V. ADJ) |
|||||
Ripple & Noise voltage * |
100 to 240 VAC input |
80 mVp-p max. |
90 mVp-p max. |
90 mVp-p max. |
80 mVp-p max. |
|
Input variation influence * |
0.5% max. |
|||||
Load variation influence * |
1.0% max. |
|||||
Temperature vari- ation influence |
100 to 240 VAC input |
0.03%/°C max. |
||||
Startup time * |
115 VAC input |
750 ms typ. |
750 ms typ. |
760 ms typ. |
770 ms typ. |
|
230 VAC input |
700 ms typ. |
690 ms typ. |
710 ms typ. |
720 ms typ. |
||
Hold time * |
115 VAC input |
13 ms typ. |
14 ms typ. |
14 ms typ. |
15 ms typ. |
|
230 VAC input |
74 ms typ. |
75 ms typ. |
75 ms typ. |
79 ms typ. |
||
Addi- tional func- tions |
Overload protection |
Yes, automatic reset |
||||
Overvoltage protection * |
Yes, 115% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
|||||
Overheat protection |
No |
|||||
Series operation |
Yes (For up to 2 Power Supplies, external diodes are required.) |
|||||
Parallel operation |
No (However, backup operation is possible, external diodes are required.) |
|||||
Remote sensing |
No |
|||||
Remote control |
No |
|||||
Output indicator |
Yes (LED: Green) |
|||||
Insula- tion |
Withstand voltage |
3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA |
||||
2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA |
||||||
1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA |
||||||
Insulation resistance |
100 MÙ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC |
|||||
Envi- ronment |
Ambient operating temperature |
-20 to 60°C (Derating is required according to the temperature. Refer to Derating Curves on page 17.) (with no condensation or icing) |
||||
Storage temperature |
-40 to 85°C (with no condensation or icing) |
|||||
Ambient operating humidity |
20% to 90% (Storage humidity: 10% to 95%) |
|||||
Vibration resistance |
10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
|||||
Shock resistance |
150 m/s2, 3 times each in ±X, ±Y, ±Z directions |
|||||
Reliabil- ity |
MTBF |
135,000 hrs min. |
||||
Life expectancy * |
10 years min. |
|||||
Con- struc- tion |
Dimensions (W´H´D) |
Refer to Dimensions on pages 20 and 23. |
||||
Weight |
250 g max. |
|||||
Cooling fan |
No |
|||||
Degree of protection |
--- |
|||||
Stan- dards |
Harmonic current emissions |
Conforms to EN 61000-3-2, GB17625.1 |
||||
EMI |
Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 |
||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B, GB9254 |
|||||
EMS |
Conforms to EN 61204-3 high severity levels |
|||||
Safety Standards |
Approved Standards UL : cURus UL 60950-1 (Recognition) OVC II Pol2 CSA: cURus C22.2 No60950-1 CCC: GB4943 Conformed Standards EN: EN 60950-1 OVC II Pol2 |
|||||
Marine Standards |
No |
|||||
SEMI |
No |