Omron S8FS-G15005C Power supply 150W, 100-240 VAC input, 5VDC, 21A output
Availability: Out of stock
₹ 0.0 (+18.0% GST extra)
(Min.Order)
Omron S8FS-G15005C Power Supply With Cover/Direct Mounting,Covered type,100 to 240 VAC, Power rating 150W, Output: 5VDC, 21A Terminal block (Screw terminal), Harmonic current emissions,Omron Smps,Industrial use for Switch Mode Power Supply, Omron Industrial Smps,
Power rating Item Output voltage |
150 W |
||||||
5 V |
12 V |
15 V |
24 V |
48 V |
|||
Efficiency *1 |
100 VAC input |
78% typ. |
84% typ. |
85% typ. |
87% typ. |
85% typ. |
|
200 VAC input |
81% typ. |
87% typ. |
88% typ. |
89% typ. |
88% typ. |
||
230 VAC input |
81% typ. |
87% typ. |
88% typ. |
90% typ. |
88% typ. |
||
Input |
Voltage range * |
Single phase, 85 to 264 VAC, 80 to 370 VDC |
|||||
Frequency * |
50 /60 Hz (47 to 450 Hz) |
||||||
Current * |
100 VAC input |
3 A typ. |
|||||
200 VAC input |
1.8 A typ. |
||||||
Power factor |
--- |
||||||
Leakage current * |
100 VAC input |
0.5 mA max. |
|||||
200 VAC input |
1 mA max. |
||||||
Inrush current * (for a cold start at 25°C) |
100 VAC input |
14 A typ. |
|||||
200 VAC input |
28 A typ. |
||||||
Output |
Rated Output Current |
21 A |
13 A |
10 A |
6.5 A |
3.3 A |
|
Voltage adjustment range * |
-10% to 15% (with V.ADJ) |
||||||
Ripple & Noise voltage * |
100 to 240 VAC input |
100 mVp-p max. |
110 mVp-p max. |
80 mVp-p max. |
110 mVp-p max. |
120 mVp-p max. |
|
Input variation influence * |
0.5% max. |
||||||
Load variation influence * |
1.0% max. |
||||||
Temperature variation influence |
100 to 240 VAC input |
0.05%/°C max. |
|||||
Startup time * |
100 VAC input |
1,000 ms max. |
|||||
200 VAC input |
1,000 ms max. |
||||||
Hold time * |
100 VAC input |
14 ms typ. |
10 ms typ. |
10 ms typ. |
10 ms typ. |
11 ms typ. |
|
200 VAC input |
80 ms typ. |
55 ms typ. |
55 ms typ. |
55 ms typ. |
55 ms typ. |
||
Additional functions |
Overload protection |
Yes, automatic reset |
|||||
Overvoltage protection * |
Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again) |
||||||
Overheat protection |
No |
||||||
Series operation |
Yes (For up to two Power Supplies, external diodes are required.) |
||||||
Parallel operation |
No (However, backup operation is possible, external diodes are required.) |
||||||
Remote sensing |
No |
||||||
Remote control |
Yes (Only for models with remote control option) |
||||||
Output indicator |
Yes (LED: Green) |
||||||
Insulation |
Withstand voltage |
3 kVAC for 1 min.(between all input terminals and output terminals) current cutoff 20 mA |
|||||
2 kVAC for 1 min.(between all input terminals and PE terminals) current cutoff 20 mA |
|||||||
1 kVAC for 1 min.(between all output terminals and PE terminals) current cutoff 20 mA |
|||||||
Only Remote control 500 VAC for 1 min.(between all output terminals and RC terminals) current cutoff 20 mA |
|||||||
Insulation resistance |
100 MÙ min.(between all output terminals and all input terminals/PE terminals) at 500 VDC |
||||||
Environment |
Ambient operating temperature |
-20 to 70°C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing) |
|||||
Storage temperature |
-25 to 75°C (with no condensation or icing) |
||||||
Ambient operating humidity |
90% max. (Storage humidity: 90% max.) |
||||||
Vibration resistance |
10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions |
||||||
Shock resistance |
150 m/s2, 3 times each in ±X, ±Y, ±Z directions |
||||||
Reliability |
MTBF |
135,000 hrs min. |
|||||
Life expectancy * |
10 years min. |
||||||
Construction |
Dimensions (W×H×D) |
Refer to Dimensions on page 23. |
|||||
Weight |
500 g |
||||||
Cooling fan |
No |
||||||
Degree of protection |
--- |
||||||
Standards |
Harmonic current emissions |
Conforms to EN 61000-3-2 (Applicable at 80% or less of the rated load.) |
|||||
EMI * |
Conducted Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B |
|||||
Radiated Emissions |
Conforms to EN 61204-3 Class B, EN 55011 Class B |
||||||
EMS |
Conforms to EN 61204-3 high severity levels |
||||||
Safety Standards |
UL 508 (Listing, excluding models with connector option or remote control option) UL 508 (Recognition, models with remote control option) UL 60950-1, UL 62368-1 (Recognition, OVCII [£ 3,000 m], Pol2) CSA C22.2 No.107.1 (excluding models with connector option or remote control option) CSA C22.2 No.60950-1, No.62368-1 (excluding models with connector option or remote control option) EN 50178 (OVCIII [£ 2,000 m], OVCII [> 2,000 m and £ 3,000 m], Pol2) EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [£ 3,000 m], Pol2) Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1) |
||||||
Marine Standards |
No |
||||||
SEMI |
Conforms to F47-0706 (200 VAC input) |