Omron

Omron S8FS-G10005CD Power supply 100W, 100-240 VAC input, 5VDC, 16A output Din Rail

Availability: Out of stock


0 / Piece | (Inc GST)
0.0  (+18.0% GST extra)
1 Piece/Pieces
(Min.Order)

Quantity
Quantity Price
1 - 10000 0

Omron S8FS-G10005CD Power Supply With Cover/DIN Rail Mounting,Covered type,100 to 240 VAC, Power rating 100W, Output: 5VDC, 16A Terminal block (Screw terminal), Harmonic current emissions,Omron Smps,Industrial use for Switch Mode Power Supply, Omron Industrial Smps,

Power rating

Item                                                     Output voltage

100 W

5 V

12 V

15 V

24 V

 

Efficiency *

100 VAC input

79% typ.

84% typ.

85% typ.

87% typ.

200 VAC input

81% typ.

86% typ.

87% typ.

89% typ.

230 VAC input

81% typ.

86% typ.

87% typ.

89% typ.

 

 

 

 

 

Input

Voltage range *

Single phase, 85 to 264 VAC, 80 to 370 VDC

Frequency *

50/60 Hz (47 to 450 Hz)

Current *

100 VAC input

2.1 A typ.

200 VAC input

1.2 A typ.

Power factor

---

Leakage current *

100 VAC input

0.5 mA max.

200 VAC input

1 mA max.

Inrush current * (for a cold start at 25°C)

100 VAC input

14 A typ.

200 VAC input

28 A typ.

 

 

 

 

 

 

Output

Rated Output Current

16 A

8.5 A

7 A

4.5 A

Voltage adjustment range *

-10% to 15% (with V.ADJ)

Ripple & Noise voltage *

100 to 240 VAC input

70 mVp-p max.

90 mVp-p max.

100 mVp-p max.

80 mVp-p max.

Input variation influence *

0.5% max.

Load variation influence *

1.0% max.

Temperature variation influence

100 to 240 VAC input

0.05%/°C max.

Startup time *

100 VAC input

1,000 ms max.

200 VAC input

1,000 ms max.

Hold time *

100 VAC input

12 ms typ.

11 ms typ.

11 ms typ.

10 ms typ.

200 VAC input

70 ms typ.

55 ms typ.

55 ms typ.

55 ms typ.

 

 

 

 

Additional functions

Overload protection

Yes, automatic reset

Overvoltage protection *

Yes, 120% or higher of rated output voltage, power shut off (shut off the input voltage and turn on the input again)

Overheat protection

No

Series operation

Yes (For up to two Power Supplies, external diodes are required.)

Parallel operation

No (However, backup operation is possible, external diodes are required.)

Remote sensing

No

Remote control

Yes (Only for models with remote control option)

Output indicator

Yes (LED: Green)

 

 

 

Insulation

 

 

Withstand voltage

3 kVAC for 1 min. (between all input terminals and output terminals) current cutoff 20 mA

2 kVAC for 1 min. (between all input terminals and PE terminals) current cutoff 20 mA

1 kVAC for 1 min. (between all output terminals and PE terminals) current cutoff 20 mA

Only Remote control

500 VAC for 1 min. (between all output terminals and RC terminals) current cutoff 20 mA

Insulation resistance

100 MÙ min. (between all output terminals and all input terminals/PE terminals) at 500 VDC

 

 

 

Environment

Ambient operating temperature

-20 to 70°C (Derating is required according to the temperature. Refer to Engineering Data) (with no condensation or icing)

Storage temperature

-25 to 75°C (with no condensation or icing)

Ambient operating humidity

90% max. (Storage humidity: 90% max.)

Vibration resistance

10 to 55 Hz, 4.5 G max., 0.375-mm half amplitude for 2 h each in X, Y, and Z directions

Shock resistance

150 m/s2, 3 times each in ±X, ±Y, ±Z directions

Reliability

MTBF

135,000 hrs min.

Life expectancy *

10 years min.

 

 

Construction

Dimensions (W×H×D)

Refer to Dimensions on page 21.

Weight

400 g

Cooling fan

No

Degree of protection

---

 

 

 

 

 

 

 

Standards

Harmonic current emissions

Conforms to EN 61000-3-2

EMI *

Conducted Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B

Radiated Emissions

Conforms to EN 61204-3 Class B, EN 55011 Class B

EMS

Conforms to EN 61204-3 high severity levels

 

 

 

Safety Standards

UL 508 (Listing, excluding models with connector option or remote control option) UL 508 (Recognition, models with remote control option)

UL 60950-1, UL 62368-1 (Recognition, OVCII [£ 3,000 m], Pol2)

CSA C22.2 No.107.1 (excluding models with connector option or remote control option)

CSA C22.2 No.60950-1, No.62368-1 (excluding models with connector option or remote control option) EN 50178 (OVCIII [£ 2,000 m], OVCII [> 2,000 m and £ 3,000 m], Pol2)

EN/IEC 60950-1, EN/IEC 62368-1 (OVCII [£ 3,000 m], Pol2)

Conforms to EN/IEC 61558-2-16 Conforms to PELV (EN/IEC 60204-1)

Marine Standards

No

SEMI

Conforms to F47-0706 (200 VAC input)